Aluminum window technical reference
2026-10-16
How thermal breaks work, what window thermal requirements are in each market, and what changes when an aluminum window crosses a border. Every figure is traced to a named standard, code or published regulation.
Construction & performance
Thermal Break Aluminum Windows: What They Are and What the Ratings Measure
Why aluminum needs a thermal break, what PA66 GF25 polyamide does, what frame Uf values actually look like across frame materials, and which standard governs each performance property in North America versus Europe.
Specification & compliance
Aluminum Window U-Factor and SHGC by Climate Zone, Plus US Import Compliance
Code and ENERGY STAR thresholds by climate zone, national requirements in the EU, UK and Germany, why NFRC and EN ISO 10077-1 values cannot be substituted, and how the Section 232 full-customs-value duty base affects imported aluminum windows.
Reading a window specification: five checks that catch most problems
- Check the calculation method before the number. An NFRC 100 U-factor and an EN ISO 10077-1 Uw are different measurements. They are not interchangeable and one may not be substituted for the other.
- Check the SHGC sign convention. In the US ENERGY STAR Northern zone, SHGC is a minimum. In the other three zones it is a maximum. Copying the wrong direction is a common and expensive specification error.
- Check the code edition, not the newest one. IECC U-factor limits changed between the 2021 and 2024 editions. Confirm what the authority having jurisdiction has actually adopted.
- Check whether the report matches your exact configuration. A test or simulation report covers the glazing build, hardware, opening type and dimensions it was run on. A different glass build is a different product.
- Check what is declared versus what is claimed. Anything not on the Declaration of Performance or the NFRC label is not certified, however confidently it appears in a brochure.
Standards referenced in this library
- EN 14351-1:2006+A2:2016 — windows and external pedestrian doorsets, CE marking under CPR (EU) 305/2011
- EN ISO 10077-1 and EN ISO 10077-2 — whole-window thermal transmittance calculation
- EN 12207, EN 12208, EN 12210 — air permeability, watertightness, wind resistance classification
- NFRC 100 — North American fenestration U-factor simulation
- IECC 2024 / IRC N1102 — US code maximum U-factors by climate zone
- ENERGY STAR windows, doors and skylights — certification thresholds by climate zone
- Approved Document L Volume 1 (England) — new dwellings and replacements
- GB/T 8478-2020 Aluminium Doors and Windows — Chinese national product standard
- Section 232 tariffs on aluminum, steel and copper — Proclamations 11021 and 11032